Exam FocuscardiovascularPhysiology

ECG Basics: Reading the Heart's Electrical Signal

Overview

The electrocardiogram records the summed electrical activity of the heart as seen from the body surface — a graph of voltage versus time, not a tracing of contraction or blood flow. Each heartbeat produces a P wave (atrial depolarization), a QRS complex (ventricular depolarization), and a T wave (ventricular repolarization). The flat segments between them carry timing information: the PR interval reflects conduction delay through the AV node, and the QRS width reflects how fast the ventricles depolarize. Because every electrical event triggers a mechanical one a moment later, the ECG lets you read the timing of the entire cardiac cycle.

Learning objectives

  • Label the P wave, QRS complex, and T wave and state which electrical event each represents.
  • State normal values for the PR interval and QRS duration and explain what prolongation implies about conduction.
  • Describe ECG calibration (paper speed and voltage scale) and use it to estimate heart rate.
  • Name the limb and chest leads and explain why multiple views of the heart are recorded.
  • Map each ECG deflection onto the mechanical phases of the cardiac cycle.

Process steps

1
SA node fires: atrial depolarization (P wave)

The sinoatrial node discharges spontaneously and the wave of depolarization sweeps across both atria, inscribing the small, rounded P wave. Atrial muscle contracts just after depolarizing, producing atrial systole — the ‘atrial kick’ that completes ventricular filling.

2
AV nodal delay: the PR segment

The impulse slows markedly in the atrioventricular node (about a 0.1-second delay), inscribing the flat PR segment. This pause lets the ventricles finish filling before they contract. The full PR interval, from the start of the P wave to the start of the QRS, normally measures 0.12 to 0.20 seconds.

3
Rapid ventricular depolarization: the QRS complex

The impulse races down the bundle of His and Purkinje fibers, depolarizing the ventricles from apex to base in under 0.12 seconds and inscribing the sharp QRS complex. Ventricular contraction follows almost immediately — the QRS is the electrical trigger for systole and S1.

4
The ST segment: the plateau

With the ventricles fully depolarized, no net current flows and the tracing sits flat at the baseline — the ST segment. It corresponds to phase 2 (plateau) of the ventricular action potential, when calcium influx sustains contraction during early ejection.

5
Ventricular repolarization: the T wave

The ventricles repolarize from epicardium to endocardium, inscribing the broader, asymmetric T wave. Repolarization ends the plateau, intracellular calcium falls, and the ventricles begin to relax — the electrical prelude to S2 and diastole.

6
Electrical events drive mechanical events

Each deflection precedes its mechanical consequence by a fraction of a second: P before atrial systole, QRS before ventricular systole, T before relaxation. The ECG therefore predicts the mechanical cycle — but it records electricity, not pressure, flow, or contraction itself.

7
One P-QRS-T sequence per heartbeat

Each cardiac cycle produces one P wave, one QRS complex, and one T wave in normal sinus rhythm. Heart rate is read from the R-R interval: at 25 mm/s, divide 300 by the number of large (5-mm) boxes between consecutive R waves — 4 large boxes means 75 beats per minute.

Key variables

VariableUnitTypical rangeRole
Heart ratebeats/min60–100 (normal sinus rhythm)Derived from the R-R interval; 300 divided by the number of large boxes between R waves at standard paper speed.
PR intervalseconds0.12–0.20Time from atrial depolarization onset through AV nodal conduction; screens AV node function and the filling delay.
QRS durationseconds< 0.12Speed of ventricular depolarization via the His-Purkinje system; widening indicates slowed or abnormal conduction.
QT intervalseconds~0.36–0.44 (rate-dependent)Total duration of ventricular depolarization plus repolarization; shortens physiologically as heart rate increases.
ECG calibrationmm/s; mm/mV25 mm/s; 10 mm/mVStandard paper speed and voltage gain; every time and voltage measurement on the tracing depends on these settings.

What the ECG actually measures

Each cardiac cell depolarizes and repolarizes in sequence, and the ECG sums these tiny currents into waves of voltage recorded from the skin. By convention, a wave of depolarization moving toward a positive electrode inscribes an upward deflection. Standard calibration is 25 mm per second horizontally (so each small 1-mm box = 0.04 s) and 10 mm per millivolt vertically.

Electricity, not contraction

The ECG shows electrical events only. A normal QRS means the ventricles depolarized — it does not prove they contracted effectively or ejected blood.

The waves: P, QRS, T

The P wave is atrial depolarization spreading from the SA node; atrial contraction follows. The sharp QRS complex is rapid ventricular depolarization via the His-Purkinje system — the ventricles' electrical ‘all clear’ before they contract. The broader T wave is ventricular repolarization, after which the ventricles relax. Atrial repolarization exists too, but it is buried inside the QRS complex.

The intervals: PR, QRS, QT

The PR interval (0.12–0.20 s) measures conduction from atrial start through the AV node's deliberate delay — time bought for ventricular filling. The QRS duration (under 0.12 s) measures how fast the ventricles depolarize; a wide QRS means slow, abnormal spread. The QT interval covers total ventricular electrical systole (depolarization plus repolarization) and shortens as heart rate rises.

Two numbers to memorize

PR interval 0.12–0.20 s; QRS duration less than 0.12 s. These two intervals screen the AV node and the ventricular conduction system on every ECG.

Paper speed, calibration, and heart rate

At 25 mm/s, one small box is 0.04 s and one large box (5 mm) is 0.20 s. Heart rate comes from the R-R interval: 300 divided by the number of large boxes between consecutive R waves (300, 150, 100, 75, 60, 50…). A quick check: an R-R of 4 large boxes means 75 beats per minute.

Twelve leads: twelve viewpoints

The standard ECG uses 12 leads: six limb leads (I, II, III, aVR, aVL, aVF) viewing the heart in the frontal plane, and six chest leads (V1–V6) sweeping across the front of the chest in the horizontal plane. Each lead sees the same electrical events from a different angle, which is why a deflection can be upright in one lead and inverted in another.

From electricity to mechanics

Every ECG event precedes its mechanical partner: the P wave comes just before atrial systole, the QRS just before ventricular systole and S1, and the T wave just before ventricular relaxation and S2. Reading them together — ECG, pressure curves, and heart sounds — gives the complete picture of one heartbeat.

Key points

  • The ECG records summed electrical activity — voltage versus time — not contraction or blood flow.
  • P wave = atrial depolarization; QRS complex = ventricular depolarization; T wave = ventricular repolarization.
  • The PR interval (0.12–0.20 s) includes the AV nodal delay that allows filling to complete.
  • A narrow QRS (< 0.12 s) means rapid, normal ventricular conduction via the His-Purkinje system.
  • At 25 mm/s, each small box is 0.04 s; heart rate = 300 ÷ large boxes between R waves.
  • The 12-lead ECG views the same events from 12 angles: 6 limb leads plus 6 chest leads.
  • Each electrical event precedes its mechanical partner: P → atrial systole, QRS → ventricular systole, T → relaxation.

Common misconceptions

✗ Myth: The QRS complex shows the ventricles contracting.

✓ Truth: The QRS shows ventricular depolarization — the electrical trigger. Contraction follows a fraction of a second later. This distinction matters: organized electrical activity can exist without effective contraction.

✗ Myth: A bigger QRS complex means a stronger heartbeat.

✓ Truth: QRS size reflects the mass of depolarizing tissue and the lead's viewpoint, not contractile strength. Voltage criteria suggest hypertrophy only in specific patterns — amplitude alone is not a strength meter.

✗ Myth: The flat line between beats means the heart is electrically silent.

✓ Truth: Between the T wave and the next P wave the heart is fully repolarized and resting, but pacemaker cells in the SA node are already drifting toward threshold — the next beat is being prepared during the ‘flat’ segment.

Practice questions

Q1. The PR interval on an ECG primarily reflects which physiological process?
  1. Ventricular muscle mass
  2. Conduction delay through the AV node
  3. Speed of Purkinje fiber conduction
  4. Duration of ventricular repolarization
Answer: B.

The PR interval (0.12–0.20 s) spans atrial depolarization plus the deliberate conduction delay in the AV node, which holds the impulse briefly so ventricular filling can complete before ventricular systole begins.

Q2. At 25 mm/s paper speed, consecutive R waves are 5 large boxes apart. What is the heart rate?
  1. 50 bpm
  2. 60 bpm
  3. 75 bpm
  4. 100 bpm
Answer: B.

Heart rate = 300 ÷ number of large boxes between R waves. 300 ÷ 5 = 60 beats per minute, the lower limit of normal sinus rhythm.

Q3. Which ECG deflection corresponds to ventricular repolarization?
  1. P wave
  2. QRS complex
  3. ST segment
  4. T wave
Answer: D.

The T wave represents ventricular repolarization. The QRS is ventricular depolarization, the P wave is atrial depolarization, and the ST segment is the isoelectric plateau between them.

Q4. A QRS duration of 0.16 seconds indicates:
  1. Faster than normal ventricular conduction
  2. Normal His-Purkinje conduction
  3. Slowed or abnormal ventricular depolarization
  4. Atrial conduction delay
Answer: C.

Normal QRS duration is under 0.12 seconds, reflecting rapid spread through the His-Purkinje system. A QRS of 0.16 s is wide, meaning the ventricles depolarized slowly or through an abnormal pathway.

Click a question to reveal the answer and explanation.

Frequently asked questions

What does ‘normal sinus rhythm’ mean on an ECG report?

It means each beat originates in the sinoatrial node: every QRS is preceded by a normal P wave, the P waves look alike, the rhythm is regular, and the rate is 60–100 per minute. It describes where the rhythm starts, not whether the heart is healthy overall.

Why is the QRS complex so much sharper than the P wave and T wave?

Speed. The His-Purkinje system distributes the impulse through the ventricles in under 0.12 seconds, so a large mass of tissue depolarizes nearly at once — a tall, narrow spike. Atrial depolarization spreads slowly cell-to-cell, and repolarization is inherently gradual, so both inscribe rounded, lower waves.

How can I quickly estimate heart rate from the ECG?

At the standard 25 mm/s paper speed, count the large (5-mm) boxes between two consecutive R waves and divide 300 by that number: 1 box = 300, 2 = 150, 3 = 100, 4 = 75, 5 = 60 bpm. This works only for regular rhythms.

Why does the ECG use 12 leads instead of just one?

Each lead views the heart's electrical activity from a different angle, like cameras around a stadium. A deflection moving toward a lead looks upright; moving away, inverted. Twelve viewpoints let clinicians localize which region of the heart generates each signal.