FoundationscardiovascularPhysiology

Cardiac Conduction: How the Heartbeat Spreads

Overview

The heartbeat is an electrical event before it is a mechanical one. A specialized conduction system generates each impulse in the sinoatrial node and distributes it so the atria contract first, then - after a deliberate delay - the ventricles contract from the apex upward. Each level of the system has its own intrinsic firing rate, providing built-in backup pacemakers if higher centers fail.

Learning objectives

  • Trace the normal conduction pathway in order
  • Explain the purpose of the AV nodal delay
  • State the intrinsic firing rates of the SA node, AV node, and Purkinje fibers
  • Describe how sympathetic and parasympathetic nerves change heart rate
  • Predict the heart rate if the SA node fails

Process steps

1
SA node fires: the primary pacemaker

The sinoatrial node, in the wall of the right atrium near the superior vena cava, spontaneously depolarizes about 60 to 100 times per minute - faster than any other part of the system, which is why it normally sets the heart rate. Its pacemaker cells leak sodium until threshold is reached, with no stable resting potential.

2
Impulse spreads across the atria

The wave of depolarization sweeps across both atria through gap junctions in about 0.1 seconds, producing the P wave and triggering atrial contraction. Internodal pathways speed the impulse toward the AV node.

3
AV node imposes the delay

At the atrioventricular node, conduction slows dramatically - the impulse takes about 0.1 seconds to cross. This delay is essential: it gives the ventricles time to finish filling while the atria contract. The AV node is the only normal electrical bridge between atria and ventricles, since the fibrous skeleton insulates the rest.

4
Bundle of His and bundle branches

The impulse enters the bundle of His, the single highway through the fibrous skeleton, then splits into right and left bundle branches traveling down the interventricular septum. Conduction here is fast, minimizing delay after the AV node.

5
Purkinje fibers ignite the ventricles

Purkinje fibers distribute the impulse rapidly throughout the ventricular walls, so depolarization sweeps from the apex upward and the ventricles contract in a wringing motion that ejects blood efficiently. The whole ventricular depolarization - the QRS complex - takes under 0.12 seconds.

6
Backup pacemakers stand ready

If the SA node fails, the AV node can pace at 40 to 60 beats per minute; if both fail, the Purkinje fibers pace at 20 to 40. Each lower pacemaker is slower, so the fastest working level always wins - a built-in hierarchy of redundancy.

Key variables

VariableUnitTypical rangeRole
SA node intrinsic ratebeats/min60-100Fastest pacemaker; normally sets the heart rate
AV node intrinsic ratebeats/min40-60Backup pacemaker; also the site of the critical conduction delay
Purkinje intrinsic ratebeats/min20-40Last-resort ventricular pacemaker
AV nodal delaysecondsAbout 0.1Lets atrial systole complete ventricular filling before ventricular contraction
Ventricular depolarization timesecondsUnder 0.12 (QRS)Fast Purkinje distribution keeps the QRS narrow

Feedback loops

Parasympathetic slowing at rest negative feedback

  1. Vagal activity releases acetylcholine at the SA and AV nodes
  2. Pacemaker firing and AV conduction slow
  3. Heart rate falls toward resting levels
  4. Baroreceptors sense the lower pressure and ease vagal tone

Sympathetic acceleration in activity positive feedback

  1. Exercise raises sympathetic output to the heart
  2. SA node fires faster and AV conduction quickens
  3. Heart rate and contractility climb
  4. Rising pressure eventually engages baroreceptor braking

The heart's electrical hierarchy

Autorhythmic cells exist at several levels, but the fastest one in working order always drives the heart because its impulses repeatedly reset the slower cells before they can fire on their own. The SA node at 60-100 beats per minute outruns the AV node (40-60) and the Purkinje fibers (20-40). This overdrive suppression is the reason the hierarchy is stable - and the reason failure at one level reveals the next.

Overdrive suppression

The fastest functional pacemaker suppresses slower ones by depolarizing them before their own threshold is reached.

Why the AV nodal delay matters

Without the roughly 0.1-second pause at the AV node, the ventricles would begin contracting before atrial systole finished filling them, and the atrial kick would be wasted. The delay is created by small-diameter, slow-conducting nodal cells. Sympathetic stimulation shortens it; parasympathetic stimulation lengthens it.

Fibrous skeleton

The atria and ventricles are electrically insulated from each other except at the AV node, so every ventricular beat must pass through this single checkpoint.

Fast distribution: His to Purkinje

Once past the AV node, speed is everything. The bundle of His, bundle branches, and Purkinje fibers conduct several times faster than ordinary muscle, delivering the impulse to the entire ventricular mass nearly at once. This coordinated, apex-first contraction is what makes ejection efficient; slow cell-to-cell spread would produce a weak, uncoordinated squeeze.

Autonomic control of rate and conduction

Sympathetic nerves release norepinephrine, steepening pacemaker depolarization (faster rate) and speeding AV conduction. Parasympathetic vagal fibers release acetylcholine, flattening pacemaker depolarization (slower rate) and slowing AV conduction. At rest, vagal tone dominates, which is why resting heart rate sits well below the SA node's intrinsic rate.

Educational only

Conduction abnormalities such as heart block are clinical conditions. This lesson describes normal physiology only.

What happens when pacemakers fail

SA node failure unmasks the AV nodal rhythm at 40-60 beats per minute; combined SA and AV failure unmasks a Purkinje ventricular rhythm at 20-40. These escape rhythms keep the heart beating but are too slow for normal activity, which is why artificial pacemakers are implanted - clinical context for study, not medical advice.

Key points

  • The impulse travels SA node, atria, AV node, bundle of His, bundle branches, Purkinje fibers.
  • The AV nodal delay (~0.1 s) lets the ventricles finish filling before they contract.
  • Intrinsic rates: SA node 60-100, AV node 40-60, Purkinje 20-40 beats per minute.
  • The fastest working pacemaker suppresses the slower ones.
  • Sympathetic input speeds the heart; parasympathetic (vagal) input slows it.

Common misconceptions

✗ Myth: The whole heart contracts at exactly the same instant

✓ Truth: The atria contract first, then the ventricles - the AV nodal delay guarantees this sequence. Even within the ventricles, the apex contracts slightly before the base, creating the wringing motion of ejection.

✗ Myth: Nerves are required to start each heartbeat

✓ Truth: The heartbeat originates in the SA node's autorhythmic cells, not in nerves. Autonomic nerves only modulate rate and conduction; a transplanted heart with no nerve connections still beats.

✗ Myth: A slower pacemaker takes over when the SA node is merely tired

✓ Truth: Lower pacemakers are continuously suppressed by the faster SA node. They only take over when SA impulses stop arriving - overdrive suppression, not fatigue-sharing.

Practice questions

Q1. The normal sequence of cardiac impulse conduction is:
  1. AV node -> SA node -> Purkinje fibers -> bundle of His
  2. SA node -> AV node -> bundle of His -> bundle branches -> Purkinje fibers
  3. Purkinje fibers -> AV node -> SA node -> ventricles
  4. SA node -> bundle of His -> AV node -> Purkinje fibers
Answer: B.

The impulse originates in the SA node, crosses the atria, pauses at the AV node, then travels the bundle of His, bundle branches, and Purkinje fibers.

Q2. The intrinsic firing rate of the AV node is approximately:
  1. 60-100 beats/min
  2. 40-60 beats/min
  3. 20-40 beats/min
  4. 100-140 beats/min
Answer: B.

The AV node fires at 40-60 beats per minute on its own, making it the backup pacemaker if the SA node fails.

Q3. The main purpose of the AV nodal delay is to:
  1. Let the ventricles fully repolarize
  2. Allow ventricular filling to complete before ventricular contraction
  3. Give the SA node time to recover
  4. Slow blood flow through the heart
Answer: B.

The ~0.1 second delay lets atrial systole finish filling the ventricles before they contract, preserving the atrial kick.

Click a question to reveal the answer and explanation.

Frequently asked questions

Why does the AV node delay the impulse?

The delay of about 0.1 seconds lets atrial contraction finish filling the ventricles before ventricular systole begins. Without it, the atrial kick would push blood against already-contracting ventricles and filling would suffer.

What sets the normal heart rate?

The SA node, firing at 60-100 beats per minute under combined autonomic control. At rest, parasympathetic vagal tone holds the rate near 60-75; sympathetic activation raises it during activity.

If the SA node fails, does the heart stop?

No. The AV node escapes at 40-60 beats per minute, and failing that, the Purkinje fibers pace the ventricles at 20-40. These backup rhythms sustain life but are too slow for exertion, so clinical treatment is needed.

How do sympathetic and parasympathetic nerves change conduction?

Sympathetic norepinephrine speeds SA firing and AV conduction; parasympathetic acetylcholine slows both. This dual control lets the heart match its rate to demand within seconds.