Cardiovascular SystemInteractive lab
Blood Pressure Regulation Lab
Cardiac Cycle Explorer
Step through the five phases of one heartbeat.
Atrial systole
The atria contract, pushing the final ~20–30% of ventricular filling (the 'atrial kick') into the ventricles. The ventricles are relaxed.
| Feature | State in this phase |
|---|---|
| AV valves (mitral & tricuspid) | Open |
| Semilunar valves (aortic & pulmonic) | Closed |
| Pressure relationship | Atrial pressure briefly exceeds ventricular pressure, driving blood through the open AV valves. |
| ECG correlation | P wave — atrial depolarization just before the atria contract. |
| Heart sound | — |
During both isovolumetric phases all four valves are closed — no blood enters or leaves, so pressure changes at constant volume. Ejection begins only when ventricular pressure exceeds arterial pressure, which forces the semilunar valves open.
Mean arterial pressure equals cardiac output times total peripheral resistance. This lab gives you sliders for heart rate, stroke volume, and vessel radius, then shows systolic, diastolic, and mean pressures. Trigger the baroreceptor reflex and watch the body correct a pressure drop on its own.
Instructions
Set resting values and record baseline systolic, diastolic, and mean pressures.
Constrict the vessels (smaller radius) and watch diastolic pressure climb.
Raise heart rate and stroke volume to simulate exercise; note which pressure rises most.
Drop the pressure suddenly and observe the baroreceptor reflex restore it.
Variables
| Variable | Unit | Range | Role |
|---|---|---|---|
| heart_rate | bpm | 40 – 180 (default 72) | Beats per minute. Raises cardiac output and shortens diastole, lifting diastolic pressure. |
| stroke_volume | mL | 30 – 130 (default 70) | Ejected volume per beat. Larger volumes widen pulse pressure. |
| vessel_radius | relative | 0.6 – 1.3 (default 1) | Relative arteriole radius. Resistance follows the fourth power of radius: small changes, big effects. |
| baroreceptor_reflex | toggle | 0 – 1 (default 1) | When enabled, the model auto-adjusts heart rate and resistance to defend mean arterial pressure. |
Expected outcomes
- State the MAP = CO x TPR relationship and define each term.
- Predict which pressure (systolic or diastolic) changes most with altered stroke volume vs. resistance.
- Explain the baroreceptor reflex response to a sudden pressure drop.
Lumped cardiovascular model using MAP = (HR x SV) x TPR with textbook resting values (~93 mmHg MAP). Vessel radius maps to resistance via the Poiseuille fourth-power relation. The baroreceptor block is a simple negative-feedback controller, not a full autonomic model. Educational values only.
Learning goals
- Apply the MAP = CO x TPR relationship.
- Distinguish the determinants of systolic vs. diastolic pressure.
- Explain short-term blood pressure regulation.